A reed relay is a simple device with a demanding job: switch a signal or a load cleanly, quickly, and without contaminating it, often at voltages that would destroy an ordinary relay. Selecting one is a matter of matching four things — switching voltage, isolation, load and package — to the circuit it will serve. Get any one of them wrong and the relay either fails early or corrupts the measurement it was meant to protect.

What a reed relay is

A reed relay combines a hermetically sealed reed switch with a coil in a single package. When the coil is energised, its magnetic field closes (or opens) the reed contacts. When the coil is de-energised, a spring in the reed returns the contacts to their rest state.

The hermetic seal is the point. The contacts are sealed inside a glass capsule, protected from dust, moisture and corrosive atmospheres. That is why reed relays are used where a clean, stable, low-resistance contact matters — test equipment, medical instruments and high-voltage switching — rather than in general-purpose power control.

The selection parameters

Switching voltage, stand-off voltage and breakdown voltage. These three are related but not the same, and the distinction matters. Switching voltage is the maximum voltage the contacts can make and break under load. Stand-off voltage is the maximum voltage the open contacts can withstand without conducting. Breakdown voltage is the dielectric limit — the voltage at which insulation fails. As a rule, breakdown is higher than stand-off, and stand-off is higher than the rated switching voltage. Choose a relay whose switching voltage exceeds your maximum working voltage with margin, and whose stand-off and breakdown ratings cover any transient or test voltage the circuit will see. If the application involves high test voltages, the breakdown rating is the number to design around.

Coil voltage. The coil voltage must match the drive circuit that will energise the relay. A coil driven below its rated voltage may not pull in reliably; a coil driven above it will overheat. For example, the HRM12-2A20 module in our high-voltage range uses a 12 V coil, while the HRM24-2A20 uses a 24 V coil — the model designation itself carries the coil voltage. Always confirm the coil voltage from the datasheet rather than assuming it from the package.

Contact form. Reed relays are offered in three basic contact forms: 1A (single-pole, normally open — the contact closes when the coil is energised), 1B (single-pole, normally closed — the contact opens when energised), and 1C (single-pole changeover — one common terminal switching between a normally open and a normally closed contact). Choose the form that matches the logic of the circuit, and remember that a changeover contact is two contacts sharing one common terminal, so its ratings are not the same as two independent contacts.

Contact rating. This is the maximum current and power the contacts can switch and carry. Switching a load is harder on contacts than carrying it, because breaking a circuit draws an arc. Check both the switching current and the carry current, and keep the switched power within the rating with margin. Exceeding the contact rating is the fastest way to shorten a reed relay’s life.

Insulation resistance. For low-level signals — the millivolt and microamp signals common in test and measurement — leakage matters as much as contact resistance. A relay with high insulation resistance keeps leakage current from corrupting a small signal or a high-impedance measurement. This is one of the main reasons a reed relay is chosen over a solid-state switch for precision work.

Operate and release time. Reed relays switch quickly, which is why they are used for multiplexing in test systems, where a relay may have to switch many times a second. If the application switches rapidly or needs tight timing, confirm the operate and release times from the datasheet and allow for them in the timing budget.

Voltage classes: 4 kV to 20 kV

High-voltage reed relays are grouped by the isolation they provide. Our range is organised into 4 kV, 6 kV, 10 kV, 15 kV and 20 kV series. The class to choose is the one above your maximum working and test voltage, with margin — not the one that merely equals it.

As an example, the HRM12-2A20 is a high-voltage reed relay module rated for 20 kVDC breakdown voltage with a 12 V coil. It sits at the top of the range, for applications where the highest isolation is required. Model designations in this family, such as HVR12-1A10-04, follow the same pattern: the designation identifies the series, coil and contact arrangement, and the full ratings for any model should always be confirmed from its datasheet before use.

Higher voltage class generally means a larger package and a higher price, so there is no advantage in over-specifying. Choose the lowest class that covers the real maximum voltage with a sensible margin.

When high-voltage isolation matters

High-voltage reed relays are not general-purpose parts. They are used where a signal or a test voltage must be switched while keeping it isolated from the rest of the system. Typical applications include semiconductor automated test equipment (ATE), where test signals must be routed without leakage; medical diagnostic equipment, where patient isolation is required; high-voltage test and measurement instruments; and hipot and cable insulation test systems, where the relay itself is part of the high-voltage path. In each case the requirement is the same: switch the voltage cleanly, and do not let it leak into the low-voltage side.

Reed vs solid-state vs electromechanical

Reed relay Solid-state relay Electromechanical relay
Контакты Sealed metal contacts, low resistance No moving contacts, semiconductor switch Metal contacts, open to the atmosphere
Изоляция High, hermetically sealed Good, but with leakage current and voltage drop Умеренный
Скорость Fast Very fast Slow
Life Long, millions of operations Very long (no wear) Shorter, contact wear and arcing
Current / power Low to moderate Умеренный High
Best for Precision switching, high-voltage isolation, test and measurement Fast, silent switching where leakage is acceptable High-power switching at low cost

The short version: choose a reed relay when the signal must stay clean and isolated; choose solid-state when speed and silence matter more than leakage; choose electromechanical when the load is heavy and the cost must be low.

Key takeaways

  • A reed relay is a hermetically sealed reed switch driven by a coil; the seal is what makes the contact clean and stable.
  • Select on switching voltage, stand-off voltage and breakdown voltage — and design around the breakdown rating when high test voltages are involved.
  • Match the coil voltage to the drive circuit, and confirm it from the datasheet.
  • Choose the contact form (1A, 1B or 1C) and the contact rating for the actual load, with margin.
  • Use the voltage class (4 kV to 20 kV) that covers the real maximum voltage; the HRM12-2A20, rated for 20 kVDC breakdown with a 12 V coil, is the top of the range.
  • Reed relays win where isolation and signal integrity matter; solid-state wins on speed; electromechanical wins on power and cost.
Work with an engineer

Need a relay recommendation for this application?

Tell us the switching voltage, load current, contact form and coil drive. Our engineers will suggest a qualified SHR AUTOSENSOR part and send the datasheet.